Siemens QA120AFC Circuit Breaker, AFCI, Combination, 20 A, 1 -Pole, 120/240 V, Fixed Trip, Plug Mounting
- Detects all three possible types of arc faults such as line-to-ground, line-to-neutral and Series
- Intended to mitigate the effects of parallel arcs by de-energizing the circuit when an arc-fault is detected
Plug-in, combination type CAFCI circuit breaker, complies with the requirements for both branch/feeder and outlet circuit CAFCIs. Required on January 1, 2008 by 2005 NEC, combination type CAFCI circuit breakers must be placed on bedroom power and lighting circuits. Protects downstream branch circuit wiring and cord sets and power supply cords. Provides ARC fault, overload and short circuit protection. UL listed. Protects against worn electrical insulation or damaged wire, misapplied or damaged plug-in appliances and equipment and loose electrical connections. 2 LEDs appear for 5 secs each time the CAFCI is turned on, up to 30 days after the last trip to indicate last known trip condition. One LED means arcing fault. Two LEDs means arcing fault to ground. 10 kA interrupting rating. UL listed, 120 VAC. Wire range 14 to 8 AWG. 1 in space, 120 V.
- Model
- QA120AFC
- UPC
- 887621216252
- Our SKU
- 7221435
- Sold by
- EA
- Factory pack
- 10
Product highlights
Specifications (21)
| Actuator Type | Toggle |
|---|---|
| Current Rating | 20 A |
| Dimensions | 3-1/4 in L x 1 in W x 3 in D |
| Frame Type | QAF |
| Interrupt Rating | 10 kA |
| Mounting Type | Plug |
| Number of Phases | 1 |
| Number of Poles | 1 |
| Terminal Type | Lug |
| Trip Type | Fixed |
| Type | AFCI Combination |
| Voltage Rating | 120/240 V |
| Wire Size | 14 to 8 AWG |
| Weight | 0.4 lb |
| Length (shipping) | 5 in |
| Width (shipping) | 13 in |
| Height (shipping) | 4 in |
| Sold as | Sold by the ea |
| Factory pack | 10 |
| Country of origin | MX |
| Shipping dimensions | 5 in long by 13 in wide by 4 in high |
Product description
Plug-in, combination type CAFCI circuit breaker, complies with the requirements for both branch/feeder and outlet circuit CAFCIs. Required on January 1, 2008 by 2005 NEC, combination type CAFCI circuit breakers must be placed on bedroom power and lighting circuits. Protects downstream branch circuit wiring and cord sets and power supply cords. Provides ARC fault, overload and short circuit protection. UL listed. Protects against worn electrical insulation or damaged wire, misapplied or damaged plug-in appliances and equipment and loose electrical connections. 2 LEDs appear for 5 secs each time the CAFCI is turned on, up to 30 days after the last trip to indicate last known trip condition. One LED means arcing fault. Two LEDs means arcing fault to ground. 10 kA interrupting rating. UL listed, 120 VAC. Wire range 14 to 8 AWG. 1 in space, 120 V.
Has actuator type Toggle, current rating 20 A, dimensions 3-1/4 in L x 1 in W x 3 in D.
Application
For use with Siemens EQ load centers
- Detects all three possible types of arc faults such as line-to-ground, line-to-neutral and Series
- Intended to mitigate the effects of parallel arcs by de-energizing the circuit when an arc-fault is detected
About this item
- What is this?
- Siemens QA120AFC Circuit Breaker, AFCI, Combination, 20 A, 1 -Pole, 120/240 V, Fixed Trip, Plug Mounting. Listed under Circuit Breakers - Arc Fault.
- What size is it?
- Shipping carton measures 5 in long by 13 in wide by 4 in high.
- What is it used for?
- For use with Siemens EQ load centers
- How fast can I get it?
- In stock at our 1587 First Avenue store. Order by 10am for same-day delivery anywhere in Manhattan.
- What's the model number?
- Model number QA120AFC, UPC 887621216252, our SKU 7221435.
Delivery and returns
- Same-day delivery in Manhattan, order by 10am
- Pickup at 1587 First Avenue, New York, NY 10028.
- Returns accepted within 30 days in original packaging with the receipt. Special-order items may be subject to a restocking fee : call the counter at (212) 535-8400.