Cutler-Hammer CH CH2L70SP Load Center, 70 A, 2 -Space, 4 -Circuit, Main Lug, NEMA 1 Enclosure, Surface Mounting
- Panels are supplied with split insulated neutrals with an insulated cross strap
- For service entrance applications, the neutral must be bonded by using the bonding strap supplied with the panel
- For service entrance applications, all that is required to bond the neutral is to loosen the bonding screw and the neutral screw directly beside it, insert the bonding strap into the neutral bar and retighten both connections
Load Centers are enclosures specifically designed to house the branch circuit breakers and wiring required to distribute power to individual circuits. They contain either a main breaker when used at the service entrance point or a main lug when used as a sub-panel to add circuits to existing service. The main breaker protects the main entire panel and can be used as a service disconnect. The branch breakers protect the wires leading to individual electrical loads such as fixtures and outlets.
- Model
- CH2L70SP
- UPC
- 782114190449
- Our SKU
- 6075436
- Sold by
- EA
- Factory pack
- 1
Product highlights
Specifications (20)
| Breaker/Load Center Type | Main Lug |
|---|---|
| Bus Bar Material | Copper |
| Cable Size | 14 to 2 AWG |
| Current Rating | 70 A |
| Enclosure Type | NEMA 1 |
| Interrupt Rating | 10 kA |
| Mounting Type | Surface |
| Number of Circuits | 4 |
| Number of Phases | 1 |
| Number Of Spaces | 2 |
| Voltage Rating | 120/240 V |
| Wiring Configuration | 3-Wire |
| Weight | 3.3 lb |
| Length (shipping) | 10.5 in |
| Width (shipping) | 5 in |
| Height (shipping) | 3.4 in |
| Sold as | Sold by the ea |
| Factory pack | 1 |
| Country of origin | US |
| Shipping dimensions | 10.5 in long by 5 in wide by 3.4 in high |
Product description
Load Centers are enclosures specifically designed to house the branch circuit breakers and wiring required to distribute power to individual circuits. They contain either a main breaker when used at the service entrance point or a main lug when used as a sub-panel to add circuits to existing service. The main breaker protects the main entire panel and can be used as a service disconnect. The branch breakers protect the wires leading to individual electrical loads such as fixtures and outlets.
Has breaker/load center type Main Lug, bus bar material Copper, cable size 14 to 2 AWG.
Application
For combination service entrance devices
- Panels are supplied with split insulated neutrals with an insulated cross strap
- For service entrance applications, the neutral must be bonded by using the bonding strap supplied with the panel
- For service entrance applications, all that is required to bond the neutral is to loosen the bonding screw and the neutral screw directly beside it, insert the bonding strap into the neutral bar and retighten both connections
Warranty
Limited Lifetime
About this item
- What is this?
- Cutler-Hammer CH CH2L70SP Load Center, 70 A, 2 -Space, 4 -Circuit, Main Lug, NEMA 1 Enclosure, Surface Mounting. Listed under 70 Amp.
- What size is it?
- Shipping carton measures 10.5 in long by 5 in wide by 3.4 in high.
- What is it used for?
- For combination service entrance devices
- How fast can I get it?
- 2 to 4 days from another distribution center.
- Is it covered by a warranty?
- Limited Lifetime
- What's the model number?
- Model number CH2L70SP, UPC 782114190449, our SKU 6075436.
Delivery and returns
- 2 to 4 days from another distribution center
- Returns accepted within 30 days in original packaging with the receipt. Special-order items may be subject to a restocking fee : call the counter at (212) 535-8400.
Others in this class